YEOMAN CL3 & CL5
Instructions for Use,
Installation and Servicing
For use in GB, IE (Great Britain and Eire)
PR1406 Issue 1 (October 2011)
IMPORTANT
THE OUTER CASING, FRONT AND GLASS PANEL BECOME EXTREMELY HOT DURING OPERATION AND WILL RESULT IN
SERIOUS INJURY AND BURNS IF TOUCHED. IT IS THEREFORE RECOMMENDED THAT A FIREGUARD COMPLYING WITH BS
8423:2002 IS USED IN THE PRESENCE OF YOUNG CHILDREN, THE ELDERLY OR INFIRM.
This product contains a Heat resistant glass panel. This panel should be checked during Installation and at each servicing
interval. If any damage is observed on the front face of the glass panel (scratches, scores, cracks or other surface defects), the
glass panel must be replaced and the appliance must not be used until a replacement is installed. Under no circumstances
should the appliance be used if any damage is observed, the glass panel is removed or broken.
This appliance is guaranteed for 2 years (subject to the conditions on page 3 of this Instruction manual). The second year of the
guarantee will only be valid if the annual service recommended in this Instruction manual has been completed by a GasSafe
registered engineer, and a copy of the service report is available for inspection by a Yeoman engineer.
These Instructions must be left with the appliance for future reference and for consultation when servicing the appliance. Please
make the customer aware of the correct operation of the appliance before leaving these instructions with them.
The commissioning sheet found on Page 3 of this Instruction manual must be completed by the Installer prior to leaving the
premises.
Balanced Flue Log Effect Fire
Vue de la page 0
1 2 3 4 5 6 ... 43 44

Résumé du contenu

Page 1 - YEOMAN CL3 & CL5

YEOMAN CL3 & CL5Instructions for Use,Installation and ServicingFor use in GB, IE (Great Britain and Eire)PR1406 Issue 1 (October 2011)IMPORTANTTHE

Page 2 - SERVICING INSTRUCTIONS 32

108. FLAME FAILURE DEVICE8.1 This is a safety feature incorporated on this appliance which automatically switches off the gas supply if the pilot goe

Page 3 - IMPORTANT NOTICE

11INSTALLATION INSTRUCTIONSTECHNICAL SPECIFICATIONCOVERING THE FOLLOWING MODELS:Model Gas CAT.Gas Type WorkingPressureAeration Injector Gas Ratem3/hIn

Page 4

12INSTALLATION INSTRUCTIONSTECHNICAL SPECIFICATIONThis appliance has been certified for use in countries other than those stated. To install this appl

Page 5

13INSTALLATION INSTRUCTIONSSITE REQUIREMENTS Note: This appliance must only be installed with the flue supplied.You must adhere to the following: 1.1

Page 6

142. REAR FLUE2.1 REAR FLUE KITYEOMAN CL BF (8526)AR0630a2200mm min550mm max Terminal dimensions: 395 x 200 x 200 mm (H x W x D) Guard supplied C

Page 7

15INSTALLATION INSTRUCTIONSSITE REQUIREMENTS3C. TOP FLUE UP AND OUT WITH ADDITIONAL BEND3.11 An additional bend can be used on the horizontal sectio

Page 8

16INSTALLATION INSTRUCTIONSSITE REQUIREMENTS5. GAS SUPPLY THIS APPLIANCE IS INTENDED FOR USE ON A GAS INSTALLATION WITH A GOVERNED METER.5.1 Before

Page 9

17 The specified clearances provide the minimum distance to combustible materials. If the appliance is intended to be installed into a non-combustibl

Page 10 - USER INSTRUCTIONS

18INSTALLATION INSTRUCTIONSINSTALLATION1AR26942.3 Remove the frame to gain complete access to the control box and the viewing aperture by lifting the

Page 11 - INSTALLATION INSTRUCTIONS

19INSTALLATION INSTRUCTIONSINSTALLATION NOTE: For Top Exit appliances the flue collar must be placed on the flue exit before the top is fitted.3.2 T

Page 12

2COVERING THE FOLLOWING MODEL: PAGEAPPLIANCE COMMISSIONING CHECKLIST 3USER INSTRUCTIONS 4 INSTALLATION INSTRUCTIONS 14 Technical Specifications

Page 13

20INSTALLATION INSTRUCTIONSINSTALLATIONFlue and Appliance Fixings4.13 Position the appliance observing appropriate clearances.4.14 Apply a bead of s

Page 14

21INSTALLATION INSTRUCTIONSINSTALLATION4B TOP EXIT - UP & OUT ENSURE THE BLACK DECORATIVE TOP AND COLLAR ARE FITTED TO THE TOP OF THE APPLIANCE

Page 15

22INSTALLATION INSTRUCTIONSINSTALLATIONFlue and Appliance Fixings4.34 Pull appliance and flue assembly away from the hearth.4.35 Drill four fixing h

Page 16

23INSTALLATION INSTRUCTIONSINSTALLATION6. LOG LAYOUT LOGS MUST BE POSITIONED ACCORDING TO THE FOLLOWING INSTRUCTIONS TO GIVE THE CORRECT FLAME EFFECT

Page 17

24INSTALLATION INSTRUCTIONSINSTALLATION17AR2103Log 26a.4 Place the third log into the groove on the right hand side and ensure it is pushed as far in

Page 18

25INSTALLATION INSTRUCTIONSINSTALLATION22AR2103Log 16b.3 Place the second log into the left hand groove on the burner tray, Diagram 23. The log shou

Page 19

267. COMPLETION OF ASSEMBLY7.1 To fit the window frame: Offer the frame to the foot of the opening and secure using 8 screws as shown, Diagram 28.2

Page 20

278.1 To light the appliance using the remote handset press the On/Off button (�) followed directly by the OK button. The appliance will emit a beep

Page 21

288.17 From the medium setting press the UP (w) button once to increase the flame setting to high. YELLOW FLAMES WILL APPEAR WHEN THE FIRE HAS GAINE

Page 22

291. COMMISSIONING THE APPLIANCE1.1 Complete the Commissioning Checklist at the front of this manual covering: — Flue checks — Gas checks — Log la

Page 23

3FLUE CHECK PASS FAIL1. Flue is correct for appliance 2. Flue flow test N/A 3. Spillage test N/A GAS CHECK 1. Gas soundness & let by test2.

Page 24

30 If there are any difficulties achieving pairing ensure that the handset is set to Channel A. To do this follow the steps below:2.8 Press the On/O

Page 25

31SERVICING INSTRUCTIONSSERVICING/FAULTFINDINGCHARTS1. SERVICING REQUIREMENTSIMPORTANT – The glass panel on this appliance should be checked for a

Page 26

32SERVICING INSTRUCTIONSFAULT FINDING CHARTSPILOT WILL NOT STAY LIT OR FIRE GOES OUT IN USEEnsure there is no debris around the pilot assembly, (e.g.

Page 27

33SERVICING INSTRUCTIONSFAULT FINDING CHARTSELECTRONIC CONTROL VALVE FAULT ANALYSIS Problem Cause Error Message LCD Display SolutionDoes not igniteNo

Page 28

2AR26932.2 Remove the frame to gain complete access to the control box and the viewing aperture by lifting the hooks clear of the slots on the front

Page 29

35SERVICING INSTRUCTIONSREPLACING PARTS 4. BAFFLE & CERAMIC LINERS4.1 To access the burner tray and interior workings of the appliance it may be

Page 30

3618AR21504.8 To replace the liners liner and baffle reverse these procedures.5. MAIN BURNER5.1 To remove the main burner: Remove the baffle and ce

Page 31 - SERVICING INSTRUCTIONS

37SERVICING INSTRUCTIONSREPLACING PARTS22AR16047.5 To remove the electrode, disconnect the ignition lead and undo the retaining nut. The electrode c

Page 32

38SERVICING INSTRUCTIONSREPLACING PARTS To change the gas valve:9.1 Disconnect the pilot pipe. 9.2 Disconnect the thermocouple, interrupter leads a

Page 33

39SERVICING INSTRUCTIONSREPLACING PARTS11.4 After replacing the control box ensure all cables and connections are refitted as detailed in Diagram 28.

Page 34

4USER INSTRUCTIONS 1. GENERAL In the event of a gas escape or if you can smell gas, please take the following steps: • Immediatelyturnoffthegas

Page 35

4013. PRIMARY AERATION PLATE NOT ALL MODELS HAVE AERATION PLATES. REFER TO NOTE AT BEGINNING OF INSTALLATION INSTRUCTIONS.13.1 Remove the burner mod

Page 36

41SERVICING INSTRUCTIONSREPLACING PARTSCL3 CL5COMPONENT NG LPG NG LPGPILOT INJECTOR PI0026 PI0015 PI0026 PI0015MAIN INJECTOR IN0040 IN0071 IN0060 IN0

Page 38

43SERVICE RECORDS1ST SERVICEDate of Service:...Next Service Due:...

Page 39

Yeoman Limited, Osprey Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7JGTel: (01392) 261999 Fax: (01392) 444148 E-mail: [email protected]

Page 40

5USER INSTRUCTIONS2.1 To light the appliance using the remote handset press the On/Off (�) button followed directly by the OK button. The appliance w

Page 41

6USER INSTRUCTIONS2.16 From the low setting press the UP (w) button once to increase the flame setting to medium.2.17 From the medium setting press

Page 42

7USER INSTRUCTIONS5. CHANGING THE YEOMAN CL BATTERIES5.1 The appliance batteries are located to the left hand side of the touch pad. This is behind t

Page 43 - SERVICE RECORDS

8USER INSTRUCTIONS7a.3 Place the second log into the left hand groove on the burner tray and ensure it is pushed as far into the centre as the groove

Page 44 - A member of the Stovax Group

9USER INSTRUCTIONS15AR2103Log 17b.3 Place the second log into the left hand groove on the burner tray, Diagram 16. The log should butt up against th